SMART CHARGE 5
TRACER GAS CHARGING SYSTEM
The Smart Charge 5 is a fully automatic, custom configurable evacuation and tracer gas backfill system with built-in gross leak test. The system is ideally suited for pre-charging of product with tracer gas, such as Helium, Hydrogen or others prior to the leak test processes. It can also be used with any gas charging application that requires evacuation and subsequent pressurization of a test product.
Main Features
- Fastest response time in the industry (less than 0.5 seconds)
- Tracer gas background suppression
- Sensitivity to 5 x 10-8 atm cc/secs
- Less than 3 minutes total start-up time
- Fully automatic calibration sequence with built-in dual purpose gas leak
- User selectable between helium and hydrogen sniffer
- Front panel key lock-out
- Sealed membrane keypad
- Fully interactive system diagnostics with multilingual displays
- High output (110dB) adjustable audio alarm
Flexible Communication Format
- Option Full duplex RS232 communication
- Option AC & DC PLC interfacing
- Option Analog outputs
- Option Data Link Software
Options
- Analog
- User I/O
- Printer
- Low pressure feature, 0-20 psig
- Nitrogen charge up 700 psig
- Barcode scanner feature
TECHNICAL SPECIFICATIONS |
---|
Power | Universal Voltage 110 vac or 220-Volt AC, 50 – 60 Hz, 6.5 amps nominal |
---|---|
Dimensions (WxHxD) | 344 x 395 x 618 mm
13.5″ x 15.5″ x 24.4″ inches |
Utility Fittings | 1⁄4” NPT female
1⁄2” NPT female for Part Evacuation |
Pressure Transducer | Resolution of 0.01 psi in vacuum mode, or in pressure mode. Accuracy of ± 0.25%. |
Valving | Fast acting pull type solenoid featuring epoxy encapsulated design |
Manifolding | Seamless tubing with compression fitting interconnects. Helium leak tested to 1.0 × 10-6 atm-cc/sec @ 700 psig |
Product Evacuation Pump | Air Driven Venturi Pump Providing ultimate vacuum level 25.5″ Hg |
Electronics | Microprocessor-based programmable logic controller |
Gauging | Digital part pressure and leak rate displayed on operator interface |