Dual independent testing chambers system

CUSTOM LEAK TEST SYSTEM FOR CONDENSERS

DUAL INDEPENDENT CHAMBER l CONDENSERS HVAC

The VIC Industrial Leak Test System is a fully automated, high-volume helium leak-testing machine designed for precision and efficiency. This self-contained system is engineered to test up to 120 parts per hour across two chambers, ensuring rapid and accurate leak detection for industrial applications.

This leak test system is a solution for leak testing condensers with our MD-490M. It can also be used for other applications.

FEATURES

  • GENERAL

    • High-Volume Testing – Capable of testing 120 parts per hour across both chambers.
    • Dual-Chamber System – Increases efficiency and throughput in production environments.
    • Automated Leak Detection – Uses V.I.C. Model MD-490M leak detectors for precise results.
    • Seamless Integration – Fully equipped with manual controls, external piping, valves, and electrical harnessing.
    • Stainless Steel Chamber Assemblies – Durable, welded construction for long-lasting performance.
    • Pneumatic Sliding Chamber Doors – Space-saving vertical motion with o-ring seals for secure closure.
    • Calibrated Helium Leak Standards – Ensures accurate test verification.Comprehensive Monitoring – Part pressure gauges attached to each chamber for real-time pressure tracking.

This system can be fully customized to meet your testing requirements.

Photo of chamber evacuation pump in operation

Chamber Evacuation Pumping

MAIN COMPONENTS

  1. Chamber Assemblies – Welded stainless steel construction with pneumatic sliding doors and o-ring seals.
  2. Operator Console & HMI – Intuitive human-machine interface for system control.
  3. Chamber Control Panel & Indicators – Provides real-time system status updates.
  4. Chamber Evacuation Pumping Packages – Ensures effective vacuum generation for leak detection.
  5. V.I.C. Model MD-490M Leak Detectors – Industry-standard detection technology for high accuracy.
  6. Part Evacuation & Charge Cabinets – Controls helium flow and evacuation for precise testing.
  7. Main Electrical Cabinet – Houses critical system electrical components.
  8. Calibrated Gas Leaks – Provides reference standards for helium leak verification.

This system is designed for high-speed, reliable helium leak detection, making it an ideal choice for industrial applications requiring precision and efficiency.

VIC instrument touchscreen interface

Main Interface

Picture of the chamber

Chamber

MD490M in action integrated into a system

MD-490M with Pump