PBS-1
GAS HANDLING SYSTEM – BOMBING STATION
SINGLE CHAMBER
Introducing the VIC PBS-1 Single Chamber Bombing Station, designed for precise helium tracer gas leak detection in automotive, aerospace, and electronics. Its single-chamber design simplifies testing, ensuring reliable identification of even the smallest leaks while reducing test times.
Main Features
- Easy to read control panel with manifolding schematic simplifies cycling of the system
- Fail-safe locking system prevents chamber from opening under pressure
- Quiet direct-drive mechanical pump with coaxial trap provides for contamination-free evacuation of the chamber
- Safety over-pressure relief valve
Operation
- Initial Startup
- Loading of Canister
- Evacuation of Canister
- Pressurization with Helium
- Bombing Period
- Venting of Canister
- Flushing the Devices
- Shutdown of Bombing Station
The PBS-1 Bombing Station can be fully customized to meet your testing needs.
SPECIFICATIONS |
---|
Chamber Size | ASME coded 9” diameter by 10-1/2” deep |
---|---|
Maximum Operating Pressure | 110 psig |
Pump | 3.2 CFM direct drive mechanical pump with coaxial trap |
Operation | Controls provide initial evacuation, venting after bombing and purging of the chamber with Nitrogen and other gases |
Valves | Manual, designed for long life |
Safety | 110 psig pressure relief valves |
Dimensions | 24” W x 23 1/2” D x 43” H |
Shipping Weight | 160 lbs |
Power Requirements | 120V, 60Hz; 220v/50Hz |